CVE-2023-32467 is a medium severity (CVSS 5.7) out-of-bounds write in the BIOS of Dell Edge Gateway 3200 and 5200 devices. A local, authenticated, high privilege user could expose UEFI code and reach code execution or privilege escalation. Dell lists BIOS v1.05.10 or later as the fix for the 5200.
What's affected
The NVD record and Dell's advisory (DSA-2023-225) describe Dell Edge Gateway BIOS versions 3200 and 5200. The advisory's remediation table lists the Edge Gateway 5200 DXE driver, versions prior to v1.05.10, with v1.05.10 or later as the fix.
There is a source conflict here. The description names both the 3200 and the 5200, but the remediation table lists only the 5200. Confirm on Dell's support page whether the 3200 is affected and which BIOS fixes it.
The weakness class on the record is CWE-665 (improper initialization), while the description speaks of an out-of-bounds write. Both appear in NVD data. The CVSS vector requires local access and high privileges, and the scope is changed, which is why the score stays in the medium range.
How to check if you're exposed
Read the BIOS version from the operating system. On Windows, in PowerShell:
Get-CimInstance Win32_BIOS | Select-Object SMBIOSBIOSVersion
On Linux, with root rights:
sudo dmidecode -s bios-version
Compare the output with the fixed version in the Dell advisory for your exact model.
What to do now
- List Edge Gateway 3200 and 5200 devices and read their BIOS versions.
- Update the 5200 to BIOS v1.05.10 or later from Dell's driver page.
- Ask Dell support or read the advisory page to confirm the 3200 status and fixed BIOS.
- Limit administrator access on these gateways to named staff.
- Record BIOS versions in your asset list so they are audited with other firmware.
Why it matters
BIOS and UEFI code runs before the operating system and with the highest rights on the machine. A memory write error there can expose firmware code, and firmware flaws can survive a reinstall of the operating system. That is why even a medium score deserves a firmware update slot.
The attacker needs local access and high privileges, which narrows the audience. Edge gateways often sit in remote sites, though, and physical or administrative access can be easier to obtain than on a data center server. The record does not report exploitation, and the KEV flag is false.
Firmware is part of your software bill of materials too. The free in-browser dependency scan covers your application dependencies, and Gold helps you follow advisories for the vendors behind your devices.
Quick check
Which BIOS version fixes CVE-2023-32467?
v1.05.10 or later for the Edge Gateway 5200, per Dell advisory DSA-2023-225.
Is the Edge Gateway 3200 affected?
The description says so, but the remediation table lists only the 5200. Check Dell before you decide.
Sources
Last reviewed: 19 October 2026.