CVE-2023-32472 is a medium severity (CVSS 5.7) out-of-bounds write in the BIOS of Dell Edge Gateway 3200 and 5200 devices. A local, authenticated, high privilege user could expose code in System Management Mode and reach code execution or privilege escalation. Dell lists BIOS v1.05.10 or later as the fix for the 5200.
What's affected
This CVE shares an advisory with CVE-2023-32467. Dell's DSA-2023-225 lists the Edge Gateway 5200 System Management Mode (SMM) component, versions prior to v1.05.10, and names v1.05.10 or later as the fixed version.
As with its sibling, the description names the 3200 and the 5200, but the remediation table lists only the 5200. Check Dell's support page for the 3200.
The weakness class on the record is CWE-787, out-of-bounds write. The vector needs local access, high privileges and no user interaction, with a changed scope. NVD and Dell agree on the 5.7 medium score.
How to check if you're exposed
Read the BIOS version from the operating system. On Windows, in PowerShell:
Get-CimInstance Win32_BIOS | Select-Object SMBIOSBIOSVersion
On Linux, with root rights:
sudo dmidecode -s bios-version
Compare the output with the fixed version in the Dell advisory for your exact model.
What to do now
- Read the BIOS version on each Edge Gateway 3200 and 5200.
- Update 5200 units to v1.05.10 or later.
- Confirm the 3200 position with Dell before closing the item.
- Review who holds administrator rights on these devices.
- Add BIOS version checks to routine audits of edge hardware.
Why it matters
System Management Mode is a special processor mode used by firmware, and code running in it is hidden from the operating system. That makes a write error in SMM code more serious than the same error in an application. Dell's wording says the flaw could expose code in that mode, leading to code execution or privilege escalation.
Reaching the flaw needs high privileges, and the attack complexity is low once those are held. In practice, the risk sits with insiders and with attackers who already control an administrator account. No exploitation is reported in the record and the KEV flag is false.
The same two CVEs share one BIOS update, so fixing one fixes the pair. See the companion post on CVE-2023-32467 for the DXE driver side. For your own code, the free in-browser dependency scan is a quick place to start.
Quick check
Is CVE-2023-32472 the same as CVE-2023-32467?
No. They share an advisory and a fix, but one concerns the DXE driver and the other System Management Mode code.
What is the fix?
BIOS v1.05.10 or later for the Edge Gateway 5200, per Dell.
Sources
Last reviewed: 19 October 2026.