Safeguard
Vulnerability Analysis•

CVE-2023-32462: Critical Command Injection in Dell OS10 Switches

CVE-2023-32462 is a critical command injection in Dell OS10 switches with remote authentication. Upgrade to 10.5.2.12, 10.5.3.8, 10.5.4.8 or 10.5.5.5.

Safeguard Security Team
3 min read

CVE-2023-32462 is a critical (CVSS 9.8) OS command injection in Dell SmartFabric OS10 networking switches that use remote user authentication. A remote unauthenticated attacker could run operating system commands. Dell lists fixes in 10.5.2.12, 10.5.3.8, 10.5.4.8 and 10.5.5.5, and recommends upgrading at the earliest opportunity.

What's affected

Dell's advisory (DSA-2023-124) says OS10 versions 10.5.2.x and above are affected. It names the 10.5.2.x, 10.5.3.x, 10.5.4.x and 10.5.5.x lines, with specific builds 10.5.5.0 and 10.5.5.3. MX builds 10.5.4.6, 10.5.5.1 and 10.5.5.2 are also listed.

Fixed versions are 10.5.2.12, 10.5.3.8, 10.5.4.8 and 10.5.5.5. For MX Series switches, the advisory points to DSA-2023-293, with fixes in 10.5.4.9 and 10.5.5.4.

The exposure depends on configuration. The flaw applies when remote user authentication is in use, such as a central authentication server. A switch using only local accounts is a different case, but check the advisory text for your build before you decide.

The record and Dell agree on the severity: a CVSS 3.1 base score of 9.8, rated critical. The weakness classes are CWE-78 (OS command injection) and CWE-20 (improper input validation).

How to check if you're exposed

Log in to each switch and print the version:

show version

Match the output to the line you run. Anything at 10.5.2.x or above and below its fixed build needs action. Then review your authentication configuration to see whether remote authentication is enabled. Your network team can export both facts from a configuration backup.

What to do now

  1. Inventory every Dell OS10 switch and read its version with show version.
  2. Plan upgrades to the fixed build for your line: 10.5.2.12, 10.5.3.8, 10.5.4.8 or 10.5.5.5. For MX Series, use 10.5.4.9 or 10.5.5.4.
  3. Schedule the work with your network change process, starting with switches reachable from less trusted networks.
  4. Limit who can reach the management and authentication interfaces while you wait.
  5. Confirm the upgrade by re-reading the version after reboot.

Why it matters

Command injection means that text sent to a program is placed into a command that the operating system then runs, without enough checking. Here the entry point is the remote authentication path, which a network device must handle before it knows who the user is. That is why the vector in the record needs no privileges and no user interaction.

A switch sits at the center of a network. Control of it can mean visibility into traffic and the ability to change how it flows. Dell calls the issue critical and says an attacker could cause severe damage. The record does not report exploitation in the wild and the KEV flag is false, but the severity alone justifies prompt scheduling.

Dell lists no workaround, so patching is the control. Use the Gold directory to track advisories on the vendors you run, and ask whether the vulnerable code is reachable in your configuration.

Try it yourself

Click through it at your own pace, or open it full screen.

Quick check

Does CVE-2023-32462 need a login first?

No. The record lists no privileges required, though Dell notes it applies when remote user authentication is in use.

Is there a workaround?

Dell lists no workaround or mitigation. Upgrade to a fixed build.

Sources

Last reviewed: 19 October 2026.

Never miss an update

Weekly insights on software supply chain security, delivered to your inbox.

We email you a link to confirm, and only then add you to the list. Unsubscribe in one click. Privacy

Self-healing security runs on Safeguard.

Your first fix PR is minutes away.

No sales call required, even your agent can complete the purchase over MCP.