CVE-2023-33472 is a high severity (CVSS 8.8) access control flaw in Scada-LTS v2.7.5.2 build 4551883606 and earlier. A low-privilege logged-in user can reach the Event Handlers function and run commands on the server. A researcher write-up says v2.7.5.3 fixes it, so upgrade there or later.

What's affected

  • Scada-LTS v2.7.5.2 build 4551883606 and earlier, per the NVD record.
  • The researcher write-up states the issue was patched in Scada-LTS v2.7.5.3.
  • Exploitation needs a valid account, even a low-privilege one, and network access to the application.

The record gives the weakness as CWE-94 (code injection). The researcher classes it as incorrect access control. Both descriptions point at the same behavior: a feature meant for administrators was usable by someone without that role.

How to check if you're exposed

Open your Scada-LTS instance as an administrator and note the version and build shown in the application. Compare it with v2.7.5.2 build 4551883606 and v2.7.5.3.

Then review accounts. List every user, note which roles they hold, and confirm that low-privilege accounts belong to people who still need them. Check whether the web interface is reachable from networks that should not see it.

If you run Scada-LTS from a container image or a built WAR file, check the image tag or build metadata the same way. The advisory material we reviewed does not give a version command, so the in-application version is the reliable source.

What to do now

  1. Upgrade Scada-LTS to v2.7.5.3 or later, following the project release notes for your deployment method.
  2. Review all user accounts and remove or disable any that are unused. Low-privilege accounts are the entry point here.
  3. Restrict network access to the Scada-LTS web interface to the management networks that need it. Industrial control tools should not sit on open networks.
  4. Check application logs and the configured Event Handlers for entries you do not recognize, and rotate any credentials that may have been reachable from the server.
  5. Add the product to your asset inventory so the next advisory reaches the right owner.

If you track software dependencies, the free in-browser dependency scan can show which of your components carry known CVEs, and the Gold directory lists the same records in one place.

Why it matters

Scada-LTS is open source supervisory control software, so a flaw that turns a minor account into command execution on the host matters more than it would in a typical web app. The Event Handlers feature can run actions and commands on the application server. According to the researcher, the server did not check that the caller was allowed to use it, so any logged-in user could.

This is a common pattern. The user interface hides the page from low-privilege users, but the server side check is missing. Hiding a menu item is not access control. The fix class is the same everywhere: enforce authorization on the server for every privileged action.

The record shows this CVE is not listed in the CISA Known Exploited Vulnerabilities catalog, and neither source we read reports exploitation in the wild.

Try it yourself

Click through it at your own pace, or open it full screen.

Quick check

Does an attacker need an account?

Yes. Both the NVD record and the researcher say a valid, low-privilege authenticated session is required. That still counts as serious where many staff or contractors hold accounts.

Is there a fixed version?

The researcher write-up says Scada-LTS v2.7.5.3 contains the patch. Confirm against the project release notes before you plan the change.

Sources

Last reviewed: 19 October 2026.

Never miss an update

Weekly insights on software supply chain security, delivered to your inbox.

We email you a link to confirm, and only then add you to the list. Unsubscribe in one click. Privacy

Self-healing security runs on Safeguard.

Your first fix PR is minutes away.

No sales call required, even your agent can complete the purchase over MCP.