Safeguard
Vulnerability Analysis•

CVE-2023-29445: High DLL Hijacking in PTC KEPServerEX

CVE-2023-29445 is a High (CVSS 7.8 per NVD) DLL search order flaw in PTC KEPServerEX allowing local privilege escalation. Check PTC's advisory for the fix.

Safeguard Security Team
3 min read

CVE-2023-29445 is a DLL search order hijacking flaw in the KEPServerEX binary, rated High (CVSS 7.8) in the NVD record. A locally authenticated adversary could plant a malicious DLL and escalate to administrator. CISA scores it 6.3. Check PTC's advisory for the fixed build.

What's affected

CISA's advisory (Update A, 12 October 2023) lists these affected products:

  • Kepware KEPServerEX version 6.14.263.0 and prior.
  • ThingWorx Kepware Server version 6.14.263.0 and prior.
  • ThingWorx Industrial Connectivity versions 8.0 to 8.5.

CISA says PTC was developing patches, expected by November 2023. The PTC support page (CS399528) did not load when fetched, so no fixed version is confirmed here. Check PTC's advisory for the current fixed build.

Source conflict: the NVD record gives CVSS 7.8 (High) for this CVE, while CISA's advisory gives a CVSS v3 base score of 6.3. Plan on the higher rating when you set priority.

How to check if you're exposed

Open the About dialog in the KEPServerEX or ThingWorx Kepware Server administration tool, or check the installed program version in Windows Settings under Apps. Compare it with the affected ranges above and with the fixed version on PTC's advisory. This is a device or appliance issue, not a package you pull from a registry, so a dependency scan will not see it. Safeguard's free in-browser scan at https://gold.safeguard.sh/scan reads dependency manifests and will not detect firmware running on hardware. Use your asset inventory instead.

What to do now

  1. Find all KEPServerEX, ThingWorx Kepware Server and ThingWorx Industrial Connectivity installs.
  2. Check PTC's advisory CS399528 for the fixed build and install it.
  3. Only run installers you downloaded from PTC, and verify them, since one of the flaws concerns tampered installers.
  4. Follow CISA's guidance: keep control system networks off the internet, behind firewalls and separated from business networks.

Why it matters

This is CWE-427, the same class as the installer issue, but in the installed binary. CISA's text says a locally authenticated adversary could escalate privileges to administrator by planting a malicious DLL in a specific directory. The NVD description says SYSTEM.

That makes it a local privilege escalation. An attacker needs a foothold on the machine first, so the risk grows on shared engineering workstations and servers where several people have accounts. Fixing folder permissions and removing unneeded write access to program directories reduces exposure while you wait for the vendor build. The CVE is not on the CISA KEV list.

Quick check

Why do the scores differ?

The NVD record lists 7.8 and CISA's advisory lists 6.3. The reason is not stated, so treat both as valid inputs.

Does it work remotely?

No. It needs local authenticated access.

Sources

Last reviewed: 19 October 2026.

Never miss an update

Weekly insights on software supply chain security, delivered to your inbox.

We email you a link to confirm, and only then add you to the list. Unsubscribe in one click. Privacy

Self-healing security runs on Safeguard.

Your first fix PR is minutes away.

No sales call required, even your agent can complete the purchase over MCP.