CVE-2023-29125 is a critical severity flaw (CVSS 9.0) in the web management software of the Enel X Waybox Pro 3.0 EV charger. A heap buffer overflow could be triggered by sending a specific packet to TCP port 7700. The vendor fixed it in firmware 2.1.1.0_JB3VU096A, delivered as a remote update to connected chargers.
What's affected
The bulletin lists the Enel X Waybox Pro 3.0 charger running firmware before 2.1.1.0_JB3VU096A. Its introduction refers to the Waybox Pro and Plus 3.0 chargers, while the affected products section names only the Pro, so owners of the Plus should confirm with the vendor.
The NVD record lists the Waybox Pro firmware and the Waybox Pro 3.0 hardware. Fixed version: 2.1.1.0_JB3VU096A, which the vendor says it delivered as a remote firmware update.
Because the record names TCP port 7700, check whether that port is reachable on your charger network.
How to check if you're exposed
There is no package to query here. Work from the charger itself and the vendor.
- List every Waybox Pro or Plus 3.0 unit you own or manage, with its location and network placement.
- Record the firmware version for each. If you cannot read it directly, ask Enel X Way support or use the Enel X Way mobile app, which the bulletin names as the route for units that are not online.
- Treat any unit on a firmware version earlier than 2.1.1.0_JB3VU096A as exposed until it is updated.
This is a device or appliance issue, not a package you pull from a registry, so a dependency scan will not see it. Safeguard's free in-browser scan at https://gold.safeguard.sh/scan reads dependency manifests and will not detect firmware running on hardware. Use your asset inventory instead.
What to do now
- Confirm each charger is on firmware 2.1.1.0_JB3VU096A or later.
- If a charger is not connected to the internet, follow the vendor's instructions in the Enel X Way mobile app to apply the update.
- Until you have confirmed the update, keep the charger's management interface off untrusted networks and limit who can reach it.
- Record the update in your asset register so the next audit can see the fixed version.
Why it matters
The NVD record says a heap buffer overflow could be triggered by sending a specific packet to TCP port 7700. The bulletin places it in a binary named CM_main.exe. It is a memory safety bug, and the record lists both heap based overflow and out of bounds write as the weakness types.
Memory corruption in a network service is harder to exploit than a logic flaw, which may be why the score is 9.0 rather than 9.6, but it can still lead to a crash or worse. The bulletin names the testing result as denial of service among the impacts of the full set of bugs.
The record classifies the weakness as CWE-122, CWE-787. The bulletin states that these issues were found by PCAutomotive and confirmed by Enel X Way, that the vendor knows of no real attacks on any installed charger, and that no personal data would be accessible in an attack. Those are the vendor's statements, and this CVE is not on the CISA Known Exploited Vulnerabilities list.
Quick check
Which port matters?
The record names TCP port 7700.
Can I block it instead of patching?
Restricting access to that port is a sensible stopgap, but the vendor fix is the firmware update.
Sources
Last reviewed: 19 October 2026.