Safeguard
Vulnerability Analysis•

CVE-2023-29120: Critical OS Command Flaw in Enel X Waybox

CVE-2023-29120 is a Critical (CVSS 9.6) OS command injection in Enel X Waybox Pro 3.0 chargers. Update the firmware to 2.1.1.0_JB3VU096A or later.

Safeguard Security Team
3 min read

CVE-2023-29120 is a critical severity flaw (CVSS 9.6) in the web management software of the Enel X Waybox Pro 3.0 EV charger. The web management application could be used to run arbitrary operating system commands with administrator privileges. The vendor fixed it in firmware 2.1.1.0_JB3VU096A, delivered as a remote update to connected chargers.

What's affected

The bulletin lists the Enel X Waybox Pro 3.0 charger running firmware before 2.1.1.0_JB3VU096A. Its introduction refers to the Waybox Pro and Plus 3.0 chargers, while the affected products section names only the Pro, so owners of the Plus should confirm with the vendor.

The NVD record lists the Waybox Pro firmware and the Waybox Pro 3.0 hardware. Fixed version: 2.1.1.0_JB3VU096A, which the vendor says it delivered as a remote firmware update.

How to check if you're exposed

There is no package to query here. Work from the charger itself and the vendor.

  1. List every Waybox Pro or Plus 3.0 unit you own or manage, with its location and network placement.
  2. Record the firmware version for each. If you cannot read it directly, ask Enel X Way support or use the Enel X Way mobile app, which the bulletin names as the route for units that are not online.
  3. Treat any unit on a firmware version earlier than 2.1.1.0_JB3VU096A as exposed until it is updated.

This is a device or appliance issue, not a package you pull from a registry, so a dependency scan will not see it. Safeguard's free in-browser scan at https://gold.safeguard.sh/scan reads dependency manifests and will not detect firmware running on hardware. Use your asset inventory instead.

What to do now

  1. Confirm each charger is on firmware 2.1.1.0_JB3VU096A or later.
  2. If a charger is not connected to the internet, follow the vendor's instructions in the Enel X Way mobile app to apply the update.
  3. Until you have confirmed the update, keep the charger's management interface off untrusted networks and limit who can reach it.
  4. Record the update in your asset register so the next audit can see the fixed version.

Why it matters

The vendor titles this issue unauthorized remote command execution. The web management application could be used to execute arbitrary operating system commands and, per the record, provide administrator privileges over the Waybox system.

OS command injection is the case where user supplied data reaches a shell or process launcher without being separated from the command. It is a well understood class, and the standard defence is to avoid shelling out, or to pass arguments as a fixed list. On an embedded device the consequence is full control of the unit, which is why the score is 9.6.

The record classifies the weakness as CWE-78. The bulletin states that these issues were found by PCAutomotive and confirmed by Enel X Way, that the vendor knows of no real attacks on any installed charger, and that no personal data would be accessible in an attack. Those are the vendor's statements, and this CVE is not on the CISA Known Exploited Vulnerabilities list.

Quick check

What does the attacker gain?

Per the record, administrator privileges over the Waybox system through arbitrary OS commands.

What should I do first?

Confirm firmware is 2.1.1.0_JB3VU096A or later and keep the management interface away from untrusted networks.

Sources

Last reviewed: 19 October 2026.

Never miss an update

Weekly insights on software supply chain security, delivered to your inbox.

We email you a link to confirm, and only then add you to the list. Unsubscribe in one click. Privacy

Self-healing security runs on Safeguard.

Your first fix PR is minutes away.

No sales call required, even your agent can complete the purchase over MCP.