Safeguard
Vulnerability Analysis•

CVE-2021-45465: High Write-What-Where in syngo fastView

CVE-2021-45465 is a high write-what-where flaw in syngo fastView BMP parsing, scored 7.8. No fix is planned, so apply the Siemens workarounds or remove it.

Safeguard Security Team
4 min read

CVE-2021-45465 is a high severity write-what-where condition in how Siemens syngo fastView parses BMP files, scored 7.8. All versions are affected, and Siemens Healthineers says no remediation is currently planned. Apply the vendor workarounds, avoid untrusted files, and remove the viewer when it is no longer needed.

What's affected

The record describes missing validation of user supplied data when parsing BMP files, which can create a write-what-where condition. An attacker could use it to execute code in the context of the current process. The vector is CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. The advisory tags it ZDI-CAN-15696 and shows that it was added to the advisory in version 1.1 on 2022-02-08.

Siemens Healthineers advisory SHSA-688797 was first published on 2021-12-14 and updated on 2022-02-08, when CVE-2021-45465 was added. It lists syngo fastView as affected in all versions, and says that currently no remediation is planned. That is the key fact for planning: there is no fixed version to move to.

The advisory scores the issue 7.8, the same as the NVD record, so the two sources agree on severity. The advisory notes that syngo fastView is a standalone viewer for DICOM images from exchange media, that it can run on any Windows PC, and that it is not a medical device and not permitted for diagnostic use.

Weakness class: CWE-123.

How to check if you're exposed

There is no patch to look for, so the check is whether the software is installed at all. Search your Windows endpoint inventory, or the installed programs list, for syngo fastView.

If it is present, find out who uses it and what files they open with it. The advisory describes a risk from a user opening a malicious file, so the people who receive DICOM media or images from outside are the ones most exposed.

Siemens says the product cannot run on its own medical workstations, so the places to look are ordinary Windows PCs, for example in reception, referral or research settings.

What to do now

  1. Search for syngo fastView across your endpoints and record every install.
  2. Apply the Siemens Healthineers workarounds: download the viewer only from the official page, avoid opening untrusted files from unknown sources, and remove it after viewing the files you need.
  3. Set an end date for any copy of the viewer that has to stay, and record who owns that decision.
  4. Contact your Siemens Healthineers Customer Service Engineer for product specific guidance, as the advisory suggests.

Why it matters

A write-what-where condition is a stronger primitive than a plain overflow. The attacker influences both the value that gets written and the address it is written to. The record files it as CWE-123. With that control, turning a crash into code execution is easier, which is why the score has high impact on confidentiality, integrity and availability.

The trigger is still a file that a person opens. Nothing here is wormable or remote on its own. The risk lives in the workflow: an outside file, a trusting user and a viewer with no patch.

Vendors sometimes decide not to fix an old, narrow tool. If you rely on one, it is worth writing down an end date for it, so a risk that was meant to be temporary does not become permanent by default.

This CVE is not listed in the CISA Known Exploited Vulnerabilities catalog, and none of the pages I read state that it is exploited in the wild. That is a statement about what is known, not a reason to delay the fix.

Quick check

Why was this CVE added later than the other two?

The advisory history shows version 1.0 on 2021-12-14 and version 1.1 on 2022-02-08, which added CVE-2021-45465.

Is the product still supported?

The advisory says only that no remediation is currently planned. Ask Siemens Healthineers about product status.

Sources

Last reviewed: 19 October 2026.

Never miss an update

Weekly insights on software supply chain security, delivered to your inbox.

We email you a link to confirm, and only then add you to the list. Unsubscribe in one click. Privacy

Self-healing security runs on Safeguard.

Your first fix PR is minutes away.

No sales call required, even your agent can complete the purchase over MCP.