CVE-2021-42028 is a high severity out-of-bounds write in how Siemens syngo fastView parses BMP files, scored 7.8. All versions are affected, and Siemens Healthineers says no remediation is currently planned. Apply the vendor workarounds, avoid untrusted files and remove the viewer when you are done with it.
What's affected
This record describes a lack of validation of user supplied data when parsing BMP files. The result can be an out-of-bounds write past the end of an allocated structure, which an attacker could use to execute code in the context of the current process. The vector is CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. The advisory tags it with the identifier ZDI-CAN-14860.
Siemens Healthineers advisory SHSA-688797 was first published on 2021-12-14 and updated on 2022-02-08, when CVE-2021-45465 was added. It lists syngo fastView as affected in all versions, and says that currently no remediation is planned. That is the key fact for planning: there is no fixed version to move to.
The advisory scores the issue 7.8, the same as the NVD record, so the two sources agree on severity. The advisory notes that syngo fastView is a standalone viewer for DICOM images from exchange media, that it can run on any Windows PC, and that it is not a medical device and not permitted for diagnostic use.
Weakness class: CWE-787.
How to check if you're exposed
There is no patch to look for, so the check is whether the software is installed at all. Search your Windows endpoint inventory, or the installed programs list, for syngo fastView.
If it is present, find out who uses it and what files they open with it. The advisory describes a risk from a user opening a malicious file, so the people who receive DICOM media or images from outside are the ones most exposed.
Siemens says the product cannot run on its own medical workstations, so the places to look are ordinary Windows PCs, for example in reception, referral or research settings.
What to do now
- Search for syngo fastView across your endpoints and record every install.
- Apply the Siemens Healthineers workarounds: download the viewer only from the official page, avoid opening untrusted files from unknown sources, and remove it after viewing the files you need.
- Block or quarantine image attachments from unknown senders on machines that have the viewer installed.
- Contact your Siemens Healthineers Customer Service Engineer for product specific guidance, as the advisory suggests.
Why it matters
This is a sibling of the DICOM parsing flaw in the same product, but the entry point is different. BMP is an image format that looks simple, which is part of the problem: simple formats get less attention in code review, and a viewer may accept BMP files from places where DICOM files are not expected, like email attachments. The record files it as CWE-787, out-of-bounds write.
A viewer that handles several formats has a parser for each one, and every parser is a place for the same mistake. A fix in one parser does not tell you anything about the others, which is why the advisory carries more than one CVE.
With no fix on offer, the useful questions are procedural. Where do BMP files come from, who opens them, and does that person's account hold data worth stealing? Answer those and the compensating controls follow.
This CVE is not listed in the CISA Known Exploited Vulnerabilities catalog, and none of the pages I read state that it is exploited in the wild. That is a statement about what is known, not a reason to delay the fix.
Quick check
How is this different from CVE-2021-40367?
Same product and the same advisory, but this one is in BMP file parsing and the other is in DICOM parsing. Both score 7.8.
What are the vendor workarounds?
Download the viewer only from the official page, avoid opening untrusted files from unknown sources, and remove the viewer after viewing the files you need.